Profrssional Animal Clinical Surgery Operation Instrument Portable Anesthesia Machine BAM-5 Pro
Professional for Veterinary
Pneumatically
Intelligent Veterinary Anesthesia Ventilator
Application: Operating room, Endoscopic operating room, CTroom, Teaching hospital, etc.
Specially use for big animal and small animal anesthesia ventilator,could widely apply in vet hospital,animal R&D institute,university university laboratory,animal clinic,animal zoo,etc.
Features
1.Simply enter the animal's weight and our system will automatically match other key parameters like respiratory rate, tidal volume, and peak airway pressure. This ensures precise ventlation for dogs and cats without the need for manual adjustments.
2.BAM-5 Pro offers VCV and PVC modes, providing veterinarians and animals with versatle ventilation options.
3.The bellows come in two sizes:20-300ml and 300-1500ml.
4.Touch-sensitive screens sionificantly enhance the speed of date input compared to traditional knob adiustment, while also delivering a seamless and comfortable human-computer interaction experience.
5.Touch-sensitive screens ofer a time -saving and convenient experience, particularly for veterinarians unfamiliar withventilation parameters. They can directly refer to the built-in data, effortlessly acquiring mechanical ventilation skills.
6.These screens are compatible with all BV anesthesia machines and other brands.
7.With breathing mode VCV,PCV etc,meet different clinical requirement
8.With apena alarm and apena time adjustable
9.With Proximal respiratory flow monitoring,more accurate
10.With big animal bellow and small animal bellow,specially for animal use
11.The gas source hose take the high precious gas source,no leakage forever
12.Build in battery could continue more than two hours in case of power failure
13.Matching with different brand veterinary anesthesia machiner failure
Specifications
Model | BAM-5 Pro |
Tidal volume(TV) | 20-1500ml |
Breathing rate(Freg) | 1-150bpm |
Spontaneous breathing rate(Freg Spont) | 0-150bpm |
Ratio of inhalation and exhalation(l:E) | 9.9:1-1:9 adjustable |
Hold time | 0-50% |
Pressure Trigger Sensitivity(P_Tring) | 0.5-20V/min,OFF |
Flow trigger sensitivity(F Tring) | -1-20cmH20.OFF |
End-expiratory pressure | 3-20cmH20.OFF |
SlMV frequency (Fre_SlMV) | 2-60bpm |
Inspiratory time(T insp) | 0.1-12s |
Pressure support (PS) | 0-60cmH20 |
Inspiratory pressure(T_insp) | 0-60cmH20 |
Tidal volume of expiratory | 0-2500ml |
Tidal volume of inspiratory | 0-2500ml |
Minute Ventilation (MV) | Dlisplay range 0-99L/min Use range 0-25L/min |
Spontaneous minute ventilation(MV Spont) | Display range 0-99L/min Use range 0-25Wmin |
Peak pressure (Ppeak) | 0-80cmH20 |
Platform pressure (Pplat) | 0-80cmH20 |
Mean pressure (Pmean) | 0-80cmH20 |
Inhaled oxygen concntration(Fi02) | 15-100% |
End-expiratory pressure(PEEP) | 0-20cmH20 |
Driving gas pressure(Press Drive) | 0-900kpa |
Paw-T waveform | Pressure monitoring range:0-120cm H20:x-axis:0-10s |
Flow-T waveform | Y-axis:-1800-180L/minX-axis: 0-10s |
V-T waveform | Y-axis:0-2000L/min X-axis:0-10s |